The KROHNE WATERFLUX 3070 is a battery powered electromagnetic water meter for use in water abstraction wells, district metering areas (DMA) and custody transfer measurement of potable water (MI-001, OIML R49). With optional pressure and temperature sensors, the meter can also be used for leak detection, quality control and pressure management systems. Unlike mechanical water meters, the KROHNE WATERFLUX 3070 is maintenance-free and offers a much larger turn down ratio (1000:1). Its measuring tube with a rectangular and reduced cross-section enables a stable measurement even at low flow rates. Due to the optimized flow profile, the KROHNE WATERFLUX 3070 can be installed virtually anywhere without straight inlet or outlet runs – behind pipe bends, slide valves or a reduction in the pipe. Even burial installation or use in flooded areas is possible.
Specifications:
General information
- Product type: Flowmeter
- Product family name: WATERFLUX
- Product positioning: For district metering of potable water and custody transfer (CT) measurement
- Measurement principle: Electromagnetic
- Measured media: Liquids
Operating conditions
- Process pressure: max. 16 barg/230 psig
- Process temperature: -5…+70°C/+23…+158°F
Materials
- Liner: Polyamide polymer 11 (Rilsan®)
Process connections
- Flange connections: EN (1092-1): DN25…600; ASME (B 16.5): 1…24″; JIS (B 2220): 25…600A
- Thread connections; Male: G1, G1½, G2
Installation conditions
- Inlet run: 0D
- Outlet run: 0D
Approvals/Standards
- Certificates/Approvals Potable Water: DVGW, NSF, TZW, KTW, WRAS, KIWA, ACS
Communication
- Discrete outputs: Pulse, Status
- Digital outputs: Modbus RTU